Specialcavi Baldassari TRRZ02TM250 - CPR cable TRR16 telephone 2x2x0.6mm+Terra
Price: €0,85 Including VAT / LM
Code BALTRRZ02TM250
Brand Specialcavi Baldassari
EAN 2000001041871
Description
FREE CUTTINGcut to the exact length you order
Specialcavi Baldassari TRRZ02TM250 - CPR cable TRR16 telephone 2x2x0.6mm+Terra
TRR16 telephone cable by Specialcavi Baldassari with twisted pairs of 0.6 mm solid tinned copper conductors and grey R16 grade PVC sheath. It is the CPR cable for internal telephone systems, door entry and low speed data. Formation 2x2x0.6+T.Formation2x2x0.6+TOuter diameterapprox. 4.7 mmVoltage300/300 VMax temp.70 °CCPR classCca-s2,d0,a3Sold250 m coil
Choose the variant
Where it can be installed
Indoor, in conduit or trunking With 450/750 V cablessame conduit Bundled installationclass Cca ›Internal telephone systems, PBX and distribution frames
›Door entry and low voltage signal connections
›Can share conduits with 450/750 V power cables
›Not for burial or outdoor use
Outer diameter and cross-sectionsource: Specialcavi Baldassari datasheet
Outer diameter
approx. 4.7 mm
minimum 4.5 mmmaximum 4.9 mm
Approximate value declared by the manufacturer. With normal production tolerance the cable is between 4.5 and 4.9 mm.
Conductor diameter and outer diameter are different things. In telephone cables the conductor is given by the diameter of the copper wire (0.6 mm), not by the cross-section. The outer diameter is the total thickness of the cable with insulation and sheath: you need it to choose conduits and grommets.
Technical data
Electrical data
Formation2x2x0.6+T
Rated voltage Uo/U300/300 V
Sheath voltage450/750 V
Construction
Conductorsolid tinned copper class 1, diameter 0.6 mm
Insulationflame retardant PVC
SheathR16 grade PVC, grey RAL 7001
Approx. weight31 kg/km
Temperatures
Operating temperature-15 °C to +70 °C
Min installation temperature0 °C
Installation
Min bending radius8 times the outer diameter
Fire and standards
ManufacturerSpecialcavi Baldassari
CPR fire reaction classCca-s2,d0,a3 (EN 50575)
StandardsCEI 20-29, CEI 20-11, CEI 46-5, EN 50575
The code explained
?How to read the code TRR16 2x2x0.6+TTap to open the letter by letter explanation
TRR162x2x0.6+T
- Ttelecommunication cable
- RPVC insulation
- R16R16 grade PVC sheath, CPR rated
- 2x2x0.6+T2x2x0.6: twisted pairs of 0.6 mm diameter conductors, plus an earth conductor (+T)
In our item code (BALTRRZ02TM250) the first 3 letters identify the brand, or CON for generic cables; the rest repeats the manufacturer code or the cable designation with its formation.
Recommended accessorieschosen for the cross-section and the outer diameter
Cable glands for Ø 4.5-4.9 mm
Related categories
Item code BALTRRZ02TM250Manufacturer code TRRZ02TSold 250 m coil