›Upper Type 2 socket (T2S) with locking system, for Mode 3 charging
›Lower domestic 2P+E type E/F socket (16 A) with magnetic detection of the Green'up plug, for Mode 2
›Power 3.7 kW at 16 A or 4.6 kW at 20 A
›Integrated residual current protection with 6 mA DC fault current detection
›Integrated overload detection (8 s at 125% In)
›Control pushbutton for start/stop, delayed start (3h/6h/9h) and forced start
›Potential-free contact inputs (12 V=) to enable charging from an external signal: Hp/Hc (deferrable) and On/Off (non-deferrable)
›12 V= pulse output to drive a shunt trip coil on the upstream protection
›EV Charge app via Bluetooth: operating status, daily charge programming, activation/deactivation, power adjustment, software update
›IP communication interface 059056 available as an accessory
Electrical data
Rated voltage230 V single-phase (phase + N)
Frequency50/60 Hz
Rated current16/20 A
Power3.7/4.6 kW
Tolerated voltage195-265 V
Impulse voltage (Uimp)4 kV
Insulation voltage (Ui)230 V
Integrated residual current protection6 mA detection of DC fault currents
Upstream residual current protection30 mA type A or F (or type F according to local rules)
Overload detection8 s at 125% In
Conditional short-circuit4.5 kA / 6 kA / 10 kA depending on the upstream protection
Permissible thermal limit in short-circuit16 000 A²s
Stand-by consumption8.6 W
Power dissipated while charging (16 A/230 V)17.4 W
Charging
Charging modesMode 2 and Mode 3
Upper socketType 2 3P+N (single-phase compatible) with pilots, IEC 62196-2
Lower socketdomestic type E/F 2P+E (16 A-250 V), NF C 61-314 and IEC 60884-1
Extension leadsnot allowed
Connection and protection
Supply terminalsphase/neutral/earth screw terminals from 2.5 to 10 mm², rigid H07 V R/U or flexible H07 V K cables
Minimum supply cable section at 16 A / 20 A2.5 mm² / 4 mm²
RCBO (Q1) at 16 A / 20 AGN8813F16 / GN8813F20 (type F)
Shunt trip (KM1)F80ST1
Surge protective device (SPD)F10AP2
Recommended earth resistancenot above 30 Ω/N (N = number of charging points)
Connectivity
Local communicationBluetooth BLE, 2400-2483.5 MHz, 6 dBm
AppEV Charge (Android or iOS)
Environment and installation
Installationindoor or outdoor, restricted access area (off the street), wall-mounted or floor-mounted with pedestal 059052
Operating temperature-25 °C / +40 °C (peak 50 °C)
Storage temperature-25 °C / +70 °C (peak 80 °C)
Relative humidity0 to 90% non-condensing
Degree of protectionIP44 (IEC 60529), IK08 (EN 62262), with or without plugs inserted
Pollution degree3
Earthing systemTN-S, TT (IT with isolation transformer)
Corrosivity class3C2 and 4C2 according to IEC 60721-3-3
Noise level< 40 dBA at 1 m
Dimensions and weight
Dimensions (H x W x D)365 x 295 x 140 mm
Weight4 kg
With pedestal 059052 (H x W x D)1200 x 295 x 135 mm, 18.5 kg
Enclosure materialplastic
Standards
ProductIEC 61851-1, IEC TS 61439-7 (AEVCS)
Electromagnetic compatibilityIEC 61851-22
Electrical safetyClass 1 IEC 61140
Vehicle compatibility identificationNF EN 17186
InstallationIEC 60364-7-722
Identification
Legrand code058030
System / rangeGreen'up Premium
Data from Legrand catalogue product sheet and Legrand technical data sheets and instructions.