BTicino 059070: Green'Up Premium single-phase charging station 3.7/4.6 kW with built-in RFID reader and Ethernet kit. The 059070 is a Green'Up Premium plastic charging station for 1 electric vehicle, 3.7 or 4.6 kW (16 or 20 A) at 230 V. It has a built-in RFID reader and Ethernet communication kit. It charges in Mode 3 with a Type 2 socket and in Mode 1/2 with a 2P+E domestic socket. It is installed on the wall or on the floor with the 059052 pedestal. It can also be configured locally via Bluetooth with the EV Charge app.
Charging current16 / 20 ARated voltage230 V single-phase (phase + N)Tolerated voltage195 V - 265 VImpulse voltage (Uimp)4 kVSoldPer piece
Features and functions
›Settable charging current 16 or 20 A (3.7 or 4.6 kW)
›Built-in 13.56 MHz RFID badge reader, with local badge registration or badge list
›Built-in Ethernet communication kit (RJ45) with management web pages
›EV Charge app via Bluetooth for configuration and management
›Type 2 socket (T2S) for Mode 3 and 2P+E type E/F domestic socket for Mode 1/2
›Hp/Hc and On/Off dry contact inputs, Modbus RS485 connection
›Delayed start 3h / 6h / 9h and forced start
›Indoor or outdoor use, IP44 and IK08
Technical data
Electrical data
Rated voltage230 V single-phase (phase + N)
Frequency50/60 Hz
Charging current16 / 20 A
Power3.7 / 4.6 kW
Tolerated voltage195 V - 265 V
Impulse voltage (Uimp)4 kV
Stand-by consumption8.6 W
Power dissipated when charging 16 A/230 V17.4 W
Overload detection7.5 s at 125% In, 100 s at 115% In
Built-in residual current protection6 mA DC fault current detection
Permissible thermal limit in short circuit16 000 A²s
Electrical safety classClass 1 (IEC 61140)
Connection and protection
Supply terminalsPhase/Neutral/Earth screw terminals 2.5 to 10 mm²
Min. power line cross-section2.5 mm² (16 A), 4 mm² (20 A)
Upstream residual current protection30 mA type A or F
Recommended RCBOGN8813F16 (16 A) / GN8813F20 (20 A)
Shunt trip deviceF80ST1
EthernetRJ45, Cat. 6 cable (FTP/UTP)
Default web page IP address192.168.1.200
ModbusRS485 (Belden 9842 or Belden 3106A cable)
RFID and radio
RFID reader frequency13.56 MHz
Supported RFID standardsISO14443A (e.g. MIFARE Classic, MIFARE DESFire, MIFARE Ultralight), ISO14443B, ISO18092, ISO15693
BluetoothBLE, 2400 - 2483.5 MHz, 6 dBm
Environment
Operating temperature-25 °C / +40 °C (peak 50 °C)
Storage temperature-25 °C / +70 °C (peak 80 °C)
Relative humidity0 to 90% non-condensing
Protection degreeIP44 (IEC 60529)
Impact resistanceIK08 (EN 62262)
Noise level< 40 dBA at 1 m
Dimensions
Dimensions H x W x D365 x 295 x 140 mm
Weight4 kg
With 059052 pedestal1200 x 295 x 135 mm, 18.5 kg
Standards
ProductIEC 61851-1, IEC TS 61439-7 (AEVCS)
Electromagnetic compatibilityIEC 61851-22
InstallationIEC 60364-7-722
Radio directive2014/53/EU
Identification
Legrand code059070
System / rangeGreen'Up Premium
Data from Legrand catalogue product sheet and Legrand technical data sheets and instructions.
Matching products
Compatible devices
Learn more
Item code LEG059070Manufacturer code 059070EAN 3414972087278Sold per piece