Specialcavi Baldassari SO40001ZNEM100 - CPR Solar Cable for Photovoltaics H1Z2Z2-K 4mm2 BLACK
Price: €1,11 Including VAT / LM
Code BALSO40001ZNEM100
Brand Specialcavi Baldassari
EAN 0000000727105
Description
Special cable Baldassari SO40001ZNEM100 - CPR Solar Cable for Photovoltaic H1Z2Z2-K 4mm2 BLACK
Outer diameter: 5.5 mm
H1Z2Z2-K
Construction characteristics
Core: Flexible tinned copper, class 5
Insulation: Cross-linked rubber-based LSZH compound
Outer sheath: Special cross-linked rubber-based LSZH compound, UV-resistant
Colours: Black (based on RAL 9005)
Electrical characteristics
Core operating voltage:
Rated operating voltage:
1.0kV A.C. - 1.5kV D.C. (also to earth)
Maximum operating voltage:
1.2kV A.C. - 1.8kV D.C. (also to earth)
Sheath operating voltage:
Nominal operating voltage:
1.0kV A.C. - 1.5kV D.C.C. (also to earth)
Maximum operating voltage:
1.2kV A.C. - 1.8kV D.C. (also to earth)
Test voltage: 15 kV C.C
Normative reference
EN 50618
EN 60228 EN 50395
EN 50618 EN 50395 EN 62230
EN 50618 EN 50396 EN 60228
EN 60811-401 EN 50618
EN 60811-504 EN 60811-505 EN 60811-506 EN 50618
EN 60811-403 EN 50396 EN 50618
EN 60811-403 EN 50396 EN 50618
EN 50618br /> EN 50618 EN 50289-4-17 method A
EN 60068-2-78
EN 60811-503
EN 60332-1-2
EN 61034-2 (LT≥60%)
EN 50525-1
EN 50618 EN 60216-1 EN 60216-2
FIRE REACTION CLASS
EN 50575:2016 Dca- s2, d2, a1
Temperatures
Minimum operating temperature: -40°C
Maximum operating temperature: +90°C
Maximum short circuit temperature: +250°C
Applications
Cable complying with the requirements of the Construction Products Regulation (CPR EU 305/11), with the aim of limiting the production and spread of fire and smoke.Single-core halogen-free cable suitable for connecting the various elements of photovoltaic and solar systems. The H1Z2-K cable has excellent UV and weather resistance. The cable's service life is estimated at approx. 25 years (EN 50618) and the expected period of use at a maximum conductor temperature of 120°C and a maximum ambient temperature of 90°C is limited to 20,000 hours. For fixed installation outside and inside buildings, without protection or inside exposed or recessed pipes
Idone for applications outside the scope of the CPR regulation and for installations within an enclosed environment, with the exception of cases with specific risks of fire ignition/propagation where the use of cables with superior fire reaction performance (at least Cca-s3,d1,a3) is recommended.Direct or indirect underground laying permitted. Presence of water: condition AD7.