DESCRIPTION
Fantini Cosmi C58 - Daily chronothermostat, battery-operated. Electronic chronothermostat with microprocessor, with daily programming for the control of heating and air-conditioning systems.
| Model | Adjustment scale | Differential | Antigelo | Temperature adm. body temperature | Food | Contact Range |
| C58 | 2° - 62° | 0.25K | 5° | 45° | 2 Batt AA | 5(3)A 250Vac |
Two coloured buttons, one red and the other blue for adjusting the COMFORT and ECONOMY temperatures."
A slider for choosing the operating mode:" AUTO 1, AUTO 2, COMFORT, ECONOMY, ANTI-FREEZE."
A slider for the choice of operating mode: SUMMER-WINTER, with the same slider you can access programming."
Two buttons for setting the current time."
Three buttons for selecting the period of COMFORT, ECONOMYand ANTI-FREEZE."
A RESET button to restore the preset programme."
A dip switch to select ANTI-FREEZE mode 5°Cor OFF (ON at 0°C).
VISUALISATION
"Room temperature."
"Current time."
Current day."
Circular crown representing a 24-hour clock,divided into 48 red, black, red-black sectors: the red indicates the COMFORT period; the black indicates the ANTIGEL period; the red indicates the ECONOMY period. "
Possibility of displaying system statistics: hours of operation on the previous day and since the start of Intellitherm C58 operation, minimum and maximum temperature on the previous day and the time at which it was measured.
MODE OF OPERATION
Two preset programmes:" AUTO 1 and AUTO 2 differentiated (see data sheet)
3 modes of operation:
COMFORT keeps the set comfort temperature constant all day and night
ECONOMY keeps the set economy temperature constant all day and night.
ANTIGELO keeps the room temperature fixedat 5°C to protect the system from the dangers of frost (or switched off in the case of a dipswitch chosen to have the system completely switched off)
Customised scheduling with no intervention limits, even one every half hour.
3 temperatures, COMFORT and ECONOMY programmable, ANTI-FREEZE fixed (preset at 5°C).
JOLLY function to temporarily exclude the automatic programme, without modifying it, to continuously obtain the desired temperature from 1 to 240 hours (comfort, economy, off). After the set time Intellitherm will resume the automatic programme. To reduce or exclude the JOLLY period before the set time, press a button in a different colour to the crown button on the display.
Features
Front cover for battery extraction.Signalling on display in case of insufficient battery charge.Retention of all data during battery replacement.Microprocessor and CMOS circuits.double insulation.IP20 protection class.Unit weight 0.22 kg.