FREE CUTTINGcut to the exact length you order
Electric Cable H07RNF2X6 - H07RN-F Neoprene Cable 2x6mm2 - BY THE METRE
H07RN-F 450/750 V cable with EPR rubber cores and heavy black polychloroprene (neoprene) sheath. It is the flexible cable for heavy duty: resistant to oil, weather, UV rays and low temperatures, and suitable for permanent outdoor use. Formation 2x6: 2 cores of 6 mm², no yellow-green core.Formation2x6Outer diameter13.8-16.8 mmVoltage450/750 VMax temp.90 °CCPR classEcaSoldPer metre
Choose the variant
Where it can be installed
Permanent outdoorUV and ozone Bundled in buildingsclass Eca ›Extension leads, cable reels and supply of site, workshop and farm tools and machines
›Mobile connections under medium mechanical stress
›Temporary fixed installations, for example site huts and structures
›Permanent outdoor use and damp or wet locations
Outer diameter and cross-sectionsource: Baldassari Cavi, Pecso and La Triveneta Cavi catalogues
Estimated outer diameter
13.8 - 16.8 mm
typical 13.8 mmmaximum 16.8 mm
The low value is the typical production value, the high one the maximum declared by manufacturers. The cable you receive falls within this range, which varies slightly between brands and batches.
Cross-section and diameter are not the same thing. The cross-section (6 mm²) is the copper area of each conductor and determines how much current the cable can carry: the copper of a 6 mm² conductor is about 3 mm in diameter. The outer diameter is the total thickness with insulation and sheath: you need it to choose conduits, trunking and cable glands.
Technical data
Electrical data
Formation2x6
Rated voltage Uo/U450/750 V (0.6/1 kV in fixed protected installation)
Max conductor resistance at 20 °C3.3 ohm/km
Approx. current rating
Mobile use in air at 30 °C43 A
Fixed protected installation in air at 30 °C56 A
Construction
Conductorflexible annealed copper, class 5
InsulationEI4 grade ethylene propylene rubber
SheathEM2 grade polychloroprene, black
Approx. weight290-300 kg/km
Temperatures
Max operating temperature90 °C
Min installation temperature-25 °C
Min operating temperature-40 °C in fixed installation
Short-circuit temperature200 °C
Installation
Min bending radius6 times the outer diameter
Fire and standards
CPR fire reaction classEca
StandardsEN 50525-2-21, EN 50575
Approximate current ratings from the Baldassari Cavi and La Triveneta Cavi catalogues. The real value depends on installation, nearby circuits and temperature: for sizing refer to IEC 60364 / CEI 64-8 and the CEI UNEL 35024 tables.
The code explained
?How to read the code H07RN-F 2x6Tap to open the letter by letter explanation
H07RNF2x6
- Hharmonised cable to CENELEC European standards
- 07rated voltage 450/750 V
- Rrubber insulation
- Npolychloroprene (neoprene) sheath
- Fflexible conductor for mobile use
- 2x62 cores (conductors); X means there is no yellow-green core; 6 mm² is the cross-section of each conductor, that is the copper area, not the diameter
In our item code (CONH07RNF2X6) the first 3 letters identify the brand, or CON for generic cables; the rest repeats the manufacturer code or the cable designation with its formation.
Recommended accessorieschosen for the cross-section and the outer diameter
Terminals and cable lugs
Terminal blocks
Crimping tools
Cable glands for Ø 13.8-16.8 mm
Related categories
Item code CONH07RNF2X6Sold per metre