Specialcavi Baldassari ALZ75422M100 - Shielded Cable CPR FROHR16 ALARM G3 2x0.75+4x0.22mm2

Price: €1,10 Including VAT / LM
Code BALALZ75422M100
Brand Specialcavi Baldassari
EAN 2000001050507
Description

Specialcavi Baldassari ALZ75422M100 - Shielded Cable CPR FROHR16 ALARM G3 2x0.75+4x0.22mm2

ALARM FROHR16 screened cable by Specialcavi Baldassari for alarm and intruder systems, with PVC cores, aluminium tape screen with drain wire and white R16 grade PVC sheath. It complies with CPR class Cca-s2,d0,a3 and can share conduits with 450/750 V power cables. Formation 2x0.75+4x0.22.
Formation2x0.75+4x0.22Outer diameterapprox. 5.8 mmVoltage300/500 VMax temp.70 °CCPR classCca-s2,d0,a3Sold100 m coil
Choose the variant
Where it can be installed
Indoor, in conduit or trunking
With 450/750 V cablessame conduit
With 0.6/1 kV cablescategory 0 only
Outdoor
Buried
›Connection of sensors, sirens, keypads and alarm control panels
›Detection systems and low frequency signals, thanks to the overall screen
›Indoor installation in conduit, trunking or free air
›Not for burial or outdoor use: for these cases there is the G4 version
Outer diameter and cross-sectionsource: Specialcavi Baldassari datasheet
outer Ø 5.5-6.1 mmCross-section 0.75 mm²copper Ø 1.1 mm
Outer diameter
approx. 5.8 mm
minimum 5.5 mmmaximum 6.1 mm
Approximate value declared by the manufacturer. With normal production tolerance the cable is between 5.5 and 6.1 mm.
Cross-section and diameter are not the same thing. The cross-section (0.75 mm²) is the copper area of each conductor and determines how much current the cable can carry: the copper of a 0.75 mm² conductor is about 1.1 mm in diameter. The outer diameter is the total thickness with insulation and sheath: you need it to choose conduits, trunking and cable glands.
Technical data
Electrical data
Formation2x0.75+4x0.22
Rated voltage Uo/U300/500 V
Sheath voltage450/750 V, category C-4 (Uo 400 V)
Max conductor resistance at 20 °C26 ohm/km
Construction
Conductorflexible plain copper, class 5
InsulationR2 grade PVC
Screenaluminium/polyester tape with copper drain wire
SheathR16 grade PVC, white RAL 9010
Approx. weight54 kg/km
Temperatures
Operating temperature-15 °C to +70 °C
Min installation temperature0 °C
Short-circuit temperature160 °C
Installation
Min bending radius10 times the outer diameter
Fire and standards
ManufacturerSpecialcavi Baldassari
CPR fire reaction classCca-s2,d0,a3 (EN 50575)
StandardsCEI 20-29, CEI 20-11, EN 50575
The code explained
?How to read the code FROHR16 2x0.75+4x0.22Tap to open the letter by letter explanation
FROHR162x0.75+4x0.22
  • Fflexible stranded conductors
  • RPVC insulation
  • Oseveral cores laid up in a round cable
  • Haluminium tape screen
  • R16R16 grade PVC sheath, CPR rated
  • 2x0.75+4x0.22two groups of cores: 2x0.75 plus 4x0.22. The first number of each group is the number of cores, the second the cross-section in mm² (copper area, not the diameter)
In our item code (BALALZ75422M100) the first 3 letters identify the brand, or CON for generic cables; the rest repeats the manufacturer code or the cable designation with its formation.
Recommended accessorieschosen for the cross-section and the outer diameter
Terminals and cable lugs
Terminal blocks
Crimping tools
Cable glands for Ø 5.5-6.1 mm
Related categories
Item code BALALZ75422M100Manufacturer code ALZ75422Sold 100 m coil