Specialcavi Baldassari FRZ25002UM100 - CPR Cable FROR16 2X2.5mm2 - without yellow-green
Price: €1,07 Including VAT / LM
Code: BALFRZ25002UM100
Brand: Specialcavi Baldassari
EAN: 2000001161739
DESCRIPTION
Specialcavi Baldassari FRZ25002UM100 - CPR cable FROR16 2X2.5mm2 - without yellow-green
Outer diameter: 8.9 mm
FROR16 O.R. UNEL Cca
Construction characteristics
Core: Flexible red copper, class 5
Insulation: PVC-based compound, R2 quality
Cordage: Twisted/concentrically corded cores
Outer jacket: PVC-based compound, R16 quality, oil-resistant in accordance with CEI EN 60811-404
Core colours: CEI UNEL 00722 - 00725 (HD 308 S2 - EN50334)
Outer sheath colours: Grey (based on RAL 7035)
Electrical characteristics
Core operating voltage:
300/500V section ≤ 0.75 mm
450/750V section ≥ 1.00 mm
Test voltage:
2000V section ≤ 0.75 mm
2500V section ≥ 1.00 mm
Sheath operating voltage: 450/750V
Normative reference
CEI 20-29 IEC 60228
CEI 20-11 EN 50363
CEI EN 60332-3-24 Cat.C IEC 60332-3-24 Cat.C
CEI UNEL 36762
CEI EN 60811-404
FIRE REACTION CLASS
EN 50575:2016 Cca - s3, d0, a3
Temperatures
Minimum operating temperature: -25°C
Maximum operating temperature: +70°C
Maximum short-circuit temperature: +160°C
Applications
Cable for fixed laying complying with the requirements of the Construction Products Regulation (CPR EU 305/11), with the aim of limiting the production and spread of fire and smoke.
Multi-core cable for energy, control, signalling, command or measurement systems with oil-resistant outer sheath.
The non-propagation characteristics of the cable (low risk of bundling) and the small external dimensions make it particularly suitable for intercom, civil, indoor industrial and machine applications.
This cable can always be installed in coexistence with 450/750V energy cables and, if used to supply category 0 systems (nominal voltage less than or equal to 50V, if alternating current, or 120V, if direct current or non-corrugated), it can also be installed in coexistence with 0.6/1kV supplying loads with a nominal voltage of 230/400V.
This does not exclude possible problems due to electromagnetic interference.
In addition, it can also be used for occasional acyclic applications without stress.
Inground laying, even if protected, is not permitted.
Cable specification sheet guide:
The following information is contained in the cable code:
Example code: pre-code-typology-cable-number X/G number
The first 3 characters of the code are called pre-code, and can be either a generic CON which stands for conduit or the METEL pre-code of each brand. Example CSB stands for Specialcavi Baldassarri.
In the centre of the code you will usually find the type of cable. For example FG16OR16. The data sheet usually contains the technical data of the respective cable type. But if you want to find out more, you can conveniently search for information on the Internet.
Then we have two numbers separated by X or G. The first number represents the number of conductors, the second the cross-section (not the diameter) of the individual conductors. If the numbers are separated by X it means that there is no yellow-green inside the cable, if it is separated by G it means that one of the conductors is yellow-green.